<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-08 01-40-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
18 kHz 71 kHz 4702 0,2127
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,7 dBr 5,37 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 18 kHz % above 76 kHz: 0,2127 Acquired: 2024/12/08 1.39.01 Total samples: 4702 Equivalent time: 0:03:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 6,6 dBr MIN: 3,7 dBr AVE: 5,37 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2024/12/08 1.39.01) 01.26 01.28 01.30 01.32 01.34 01.36 01.38 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]